...High Voltage Shielded Cable Thumper for Cable Fault Locating The trolly high voltage surge generator is mainly used for underground cable fault locator test of voltage level of 35kV and below; And the torlley high voltage impulse generator can also be used for DC withstand voltage test of other electrical equipment. The device integrates DC high voltage source, energy storage capacitor and discharge ball gap tdr cable
Verified Supplier
|
![]() |
...HIGH VOLTAGE SILICONE CABLE FOR MOTOTOR LEAD WIRE Details: Conductor: Tinned Copper Construction: 84/0.30 Insulation: Silicone Cores: 1 Rated temperature: -60℃---+180℃ Rated Voltage: 0.6/1 kv Type: high voltage cable for motor lead wire Features: High voltage Het resistance Introduction High Voltage Silicone Cable for Motor Lead Wire, designed to provide reliable performance in high voltage...
Verified Supplier
|
![]() |
...High Voltage Power Cable Conductor: copper(Cu) Range of number of cores: 1 3 Range of cross section(mm2): 35 50 70 95 120 150 185 240 Insulation: PVC or XLPE Amoured: steel tape armoured (STA) Screened: Copper tape or copper wire braiding Inner sheath: PVC Over Sheath: PVC Rated voltage...
Verified Supplier
|
![]() |
...cable x ray high voltage cables for Medical X-ray equipment Technical Data: Electrical Data Rated voltage 75KVdc Routine test voltage (between conductor and copper braid) 90kVDC/10min Routine test voltage (between conductor) 2kVAC/5min Max D.C. Conductor resistance @20ºC ≤13.7Ω/Km Insulated conductor resistance ≥1000MΩ·Km Machnical Data:HV cable...
Verified Supplier
|
![]() |
...cable underground extra high voltage copper cable 220KV Product Description Application: Extra-high-tension cable is a kind of power cable with the continuous development ofcable technology. The cable is generally used as a central link in the large transmission system. It belongs to a high voltage cable with high...
Active Member
|
![]() |
...Cable , High Voltage Power Cables Quick details ------------------------------------------------------- – Nominal cross section:2X10 mm2 – Overall diameter Ø approx:15.2mm – Net weight approx: 362 kg/km – Conductor DC resistant at 20°C:1.83 Ω/km Electrical characteristics ------------------------------------------------------- –Rated voltage...
Verified Supplier
|
![]() |
...High Voltage Power Cables For Construction Product Description 1. Application : Used for indoor & outdoor laying,The Cable can bear a certain laying traction,but can't bear the mechanical force from outide.Single core cable can't be allowed to lay in the magnetic pipe . The Cable is used for fixed laying in the rated voltage...
Verified Supplier
|